скалыватель siecor fbc-006 цена

AutoFusion Time Control ensures lowest splice loss possible under a variety of splicing condi- tions and environments

LID-SYSTEM unit and fast Lens ProfileAlignment System (L-PAS) in one

Proven excellence over ten years of field reliability

Best for splicing old, dissimilar, or specialty fibers

System maintenance and restorationCustom attenuators: programmable splice loss (up to 10 dB)

Enterprise networks, data centers, telco, and CATV systems

Corning Cable Systems Model M90 Fusion Splicer has undergone a facelift but remains the ideal machine for long-haul telephone and CATV single-mode fiber splicing where accuracy is imperative. The LID-SYSTEM^ unit (Local Injection and Detection System) monitors light injected into the core of the fibers and provides the lowest splice loss possible with the most accu- rate loss readings in the industry.The accuracy of the LID-SYSTEM unit and its power-through splice loss measurement method eliminates the time-consuming task of evaluating splices with an OTDR. The 1300 nm LID-SYS- TEM unit first optimizes core alignment in each of the X, Y, and Z axes. When the fusion process begins, the M90 s unique Auto Fusion Time Control monitors the power level through the splice and completes the fusing process when splice loss is a minimum ensuring the best splice possible. Finally the LID-SYSTEM unit measures splice loss by comparing power levels before and after the fusion process. Over 1,000 splice loss results may be stored in memory and then printed directly from the M90 or downloaded to a PC for network management records. A newly added PCMCIA slot allows for extended memory and future upgrades.The unit also precisely evaluates the cleaved fiber ends a basic prerequisite for good splices. By clamping on fiber coating, high-strength splices can be made. Messages and splice loss results are shown on the M90 s high-contrast, large 5.5-inch color LCD. Fixed lenses magnify the X and Y views of the fibers 100 times and project the images simultaneously on the screen or to an external monitor.The M90 s new Series software stores 50 pro- grams with user-defined splicing parameters for different types of fibers. It also has seven fixed programs for standard and specialty single-mode fibers and multimode fiber, and an automatic fiber type detection feature that will inform you if you are attempting to use the wrong program for your fiber type. Splice losses up to 10.0 dB can be pro- grammed for an in-line attenuator with the char- acteristic non-reflectance of a fusion splice. With the new software upgrade tool, a customer's M90 can be upgraded with the latest software via a printer cable and PC connected to an e-mail sys- tem.In the fully automatic mode, the lighter and smaller M90 Series provides an average splice loss better than 0.02 dB for both single-mode fibers and multimode fibers.

Siecor M90 as X77. Corning Cable Systems Model M90 Fusion Splicer has undergone a facelift but remains the ideal machine for long-haul telephone and CATV single-mode fiber splicing where accuracy is imperative. The LID

Комментариев нет:

Отправить комментарий